Page view 38
DRÄGER GAS DETECTION | 38
Get on-site measurements of 8-hour exposures with the Dräger Diffusion Tubes. This gas and vapor measurement technique
provides a quick, simple, and on-site means to determine employee exposures.
Unlike Short-Term detector tubes that require a pump for operation, Dräger Diffusion Tubes rely on natural movement of the gases
and vapors to enter the tube and cause a color change. Simply read the indication on the graduated scale (ppm x hours) and
divide by the amount of hours the Dräger Diffusion Tube has been in use for a TWA measurement. No waiting, no analysis fees,
no laboratory services, no turn-around time; just on the spot measurement. The Dräger-Tube Holder allows you to place the
Dräger Diffusion Tube in the breathing zone of the people being monitored or in the suspected areas.
DRÄGER DIFFUSION (PASSIVE SAMPLING) TUBES
ORDER INFORMATION
Dräger-Tube
®
Range in Absolute Units Part No.
Acetic Acid 10/a-D 10 - 200 ppm x h 81 01 071
Ammonia 20/a-D 20 - 1,500 ppm x h 81 01 301
Butadiene 10/a-D 10 - 300 ppm x h 81 01 161
Carbon Dioxide 500/a-D 500 - 20,000 ppm x h 81 01 381
Carbon Dioxide 1%/a-D 1 - 30 Vol.% x h 81 01 051
Carbon Monoxide 50/a-D 50 - 600 ppm x h 67 33 191
Ethanol 1000/a-D 1,000 - 25,000 ppm x h 81 01 151
Hydrochloric Acid 10/a-D 10 - 200 ppm x h 67 33 111
Hydrocyanic Acid 20/a-D 20 - 200 ppm x h 67 33 221
Hydrogen Sulfide 10/a-D 10 - 300 ppm x h 67 33 091
Nitrogen Dioxide 10/a-D 10 - 200 ppm x h 81 01 111
Perchloroethylene 200/a-D 200 - 1,500 ppm x h 81 01 401
Sulfur Dioxide 5/a-D 5 - 150 ppm x h 81 01 091
Toluene 100/a-D 100 - 3,000 ppm x h 81 01 421
Trichloroethylene 200/a-D 200 - 1,000 ppm x h 81 01 441
Diffusion Tube Holder (pkg 3) 67 33 014
Diffusion (Passive Sampling) Tubes
ST-9380-2007
Dräger TWA Measurements
ST-167-2004-1000
Bio-Check Allergen Control
The house dust mite is the most common
cause of allergies. The Dräger-Bio-Check
Allergen Control rapid-test allows the user
to conduct an on-site analysis of house
dust mite allergens. The table supplied
with Dräger-Bio-Check Allergen Control
groups the exposure levels into categories
based on the scientific limit values for
house dust allergens.
DRAGER BIO-CHECK ALLERGEN CONTROL
ORDER INFORMATION
Drager Bio-Check Allergen Control (package of 5) 64 00 945