The Example Catalog Number above is 7AUSA3400N5XC (X is used to specify optional accessories).
7000 series Service Entrance Power Transfer Switches
9
Dimensions and Weights for non-bypass configurations
Type 1 and 3R Enclosures
4
A Automatic
N Non-
Automatic
C Type 1 enclosure
M Type 3R secure
double door
N Type 4 secure
double door
P Type 4X secure
double door
(316 SS)
Q Type 12 secure
double door
US Conventional
2-Position
UB Open Transition
Bypass
CUS Closed Transition
CUB Closed Transition
Bypass
DUS Delayed Transition
DUB Delayed Transition
Bypass
A Solid Neutral
(standard)
B Switched
Neutral
C Overlapping
Neutral
2
3
70, 100
150, 200
225, 250
400, 600
800,1000
1200,1600,
2000,2500,
3000
4000
C 208
D 220
E 230
F 240
H 380
J 400
K 415
L 440
M 460
N 480
P 550
Q 575
R 600
5
5X-
optional
acces-
sories
Ordering Information
Product
Neutral
Code*
Phase
Poles
Voltage
Code
Grp
Code
EnclosureAmperes
To order an ASCO 7000 SerieS Service Entrance Power Transfer Switch, complete the following catalog number.
7 A US + A + 3 + 400 + N + 5X + C
*Note. Switches rated 150, 600-3000 amps available with 2, 3 or either conventional switched neutral (4 poles) or overlapping neutral (optional). For 4 pole
applications on switches rates 150 to 400 amps (bypass switches only) and 4000 amps specify overlapping switched neutral (optional). Conventional switched neutral
is provided on delayed transition transfer products when specified.
Ampere Interrupting
Capacity (AIC) Ratings
70 - 225 25 35
250 25 35
400 35 35
600, 800 65 N/A
1000,1200 65 N/A
1600, 2000 65 100
2500, 3000 100 N/A
4000 100 N/A
Standard
Switch Rating
amps
Optional
AIC Rating (kA)
2
2
3
3
2
2
3
3
2
2
3
3
2
2
3
3
3
3
3
3
Switch Rating
amps
Phase
Poles
Neutral
Code
Type 1 Dimensions, In. (mm)
Width Height Depth
Approx. Shipping
Weight Lb. (kg)
70, 100 ,150,
200, 225
250, 400
600
1
, 800
1
1000
1
, 1200
1
1600
1
, 2000
1
2500
1
, 3000
1
STD
B, C
STD
B, C
STD
C
STD
C
STD
B, C
STD
B, C
STD
B, C
STD
B, C
STD
B, C
STD
B, C
36.5 (927)
36.5 (927)
36.5 (927)
36.5 (927)
36.5 (927)
36.5 (927)
36.5 (927)
36.5 (927)
38 (965)
38 (965)
38 (965)
38 (965)
38 (965)
38 (965)
38 (965)
38 (965)
38 (965)
38 (965)
38 (965)
38 (965)
48.5 (1232)
48.5 (1232)
48.5 (1232)
48.5 (1232)
48.5 (1232)
48.5 (1232)
48.5 (1232)
48.5 (1232)
91 (2311)
91 (2311)
91 (2311)
91 (2311)
91 (2311)
91 (2311)
91 (2311)
91 (2311)
91 (2311)
91 (2311)
91 (2311)
91 (2311)
13.25 (337)
13.25 (337)
13.25 (337)
13.25 (337)
13.25 (337)
13.25 (337)
13.25 (337)
13.25 (337)
28 (711)
28 (711)
28 (711)
28 (711)
48 (1218)
48 (1218)
48 (1218)
48 (1218)
48 (1218)
48 (1218)
72 (1829)
72 (1829)
400 (185)
408 (188)
408 (188)
416 (192)
400 (185)
408 (188)
408 (188)
416 (192)
800 (370)
820 (378)
865 (393)
846 (390)
1085 (501)
1105 (510)
1105 (510)
1134 (523)
2590 (1198)
2640 (1218)
4590 (2118)
4655 (2148)
2
2
3
3
2
2
3
3
2
2
3
3
2
2
3
3
3
3
3
3
70, 100 ,150,
200, 225
250, 400
600
1
, 800
1
1000
1
, 1200
1
1600
1
, 2000
1
2500
1
, 3000
1
STD
B, C
STD
B, C
STD
C
STD
C
STD
B, C
STD
B, C
STD
B, C
STD
B, C
STD
B, C
STD
B, C
36(914)
36(914)
36(914)
36(914)
36(914)
36(914)
36(914)
36(914)
41(1041)
41(1041)
41(1041)
41(1041)
41(1041)
41(1041)
41(1041)
41(1041)
41(1041)
41(1041)
41(1041)
41(1041)
48(1219)
48(1219)
48(1219)
48(1219)
48(1219)
48(1219)
48(1219)
48(1219)
95.5(2426)
95.5(2426)
95.5(2426)
95.5(2426)
95.5(2426)
95.5(2426)
95.5(2426)
95.5(2426)
95.5(2426)
95.5(2426)
96(2438)
96(2438)
16 (406)
16 (406)
16 (406)
16 (406)
16 (406)
16 (406)
16 (406)
16 (406)
34(864)
34(864)
34(864)
34(864)
62(1575)
62(1575)
62(1575)
62(1575)
62(1575)
62(1575)
85(2159)
85(2159)
520 (236)
530 (240)
530 (240)
548 (249)
520 (236)
530 (240)
530 (240)
548 (249)
990 (458)
1010 (467)
1010 (467)
1036 (479)
1305 (604)
1325 (613)
1325 (613)
1354 (626)
2890 (1337)
2940 (1360)
5350 (2474)
5415 (2504)
Notes: 1. Unit is designed for top and bottom cable
entry for all services
and load.
2. Enclosures for 600 – 3000 amps are free
standing.
3. When temperatures below 32° F can be
experienced, special precautions should
be taken, such as the inclusion of strip
heaters, to prevent condensation and
freezing of this condensation. This is par-
ticularly important when environmental
enclosures (Type 3R, 4 & 12) are ordered
for installation outdoors. Type 3R
enclosures are not suitable for installa-
tions conducive to windblown snow
or rain conditions.
4. Dimensional data is approximate and
subject to change. Certified dimensions
available upon request.
Type 3R enclosures are not suitable for
installations conducive to
windblown snow or rain conditions.
5. Contact ASCO for extended
warranty options.
Switch Rating
amps
Phase
Poles
Neutral
Code
Type 3R Dimensions, In. (mm)
Width Height Depth
Approx. Shipping
Weight Lb. (kg)